	wayland-server: Return 0 from read_events() in case of EAGAIN
Getting no data from the socket is not an error condition. This may happen in case of calling prepare_read() and then read_events() with no other pending readers and no data in the socket. In general, read_events() may not queue up events in the given event queue. From a given threads point of view it doesn't matter whether events were read and put in a different event queue or no events were read at all.
This commit is contained in:
		
							parent
							
								
									12cea95593
								
							
						
					
					
						commit
						becca5fcf7
					
				
					 1 changed files with 4 additions and 2 deletions
				
			
		| 
						 | 
				
			
			@ -873,8 +873,10 @@ read_events(struct wl_display *display)
 | 
			
		|||
	if (display->reader_count == 0) {
 | 
			
		||||
		total = wl_connection_read(display->connection);
 | 
			
		||||
		if (total == -1) {
 | 
			
		||||
			if (errno != EAGAIN)
 | 
			
		||||
				display_fatal_error(display, errno);
 | 
			
		||||
			if (errno == EAGAIN)
 | 
			
		||||
				return 0;
 | 
			
		||||
 | 
			
		||||
			display_fatal_error(display, errno);
 | 
			
		||||
			return -1;
 | 
			
		||||
		} else if (total == 0) {
 | 
			
		||||
			/* The compositor has closed the socket. This
 | 
			
		||||
| 
						 | 
				
			
			
 | 
			
		|||
		Loading…
	