mirror of
https://gitlab.freedesktop.org/pulseaudio/pulseaudio.git
synced 2025-11-05 13:29:57 -05:00
sink-input, source-output: Assign to reference_ratio from a single place
This makes it easy to log a message every time the reference ratio changes. I also need to add a hook for reference ratio changes, but that need will go away if the stream relative volume controls will be created by the core in the future.
This commit is contained in:
parent
8a4a4f408c
commit
f480fb38a7
6 changed files with 77 additions and 11 deletions
|
|
@ -1273,7 +1273,7 @@ void pa_sink_input_set_volume(pa_sink_input *i, const pa_cvolume *volume, bool s
|
|||
/* OK, we are in normal volume mode. The volume only affects
|
||||
* ourselves */
|
||||
set_real_ratio(i, volume);
|
||||
i->reference_ratio = i->volume;
|
||||
pa_sink_input_set_reference_ratio(i, &i->volume);
|
||||
|
||||
/* Copy the new soft_volume to the thread_info struct */
|
||||
pa_assert_se(pa_asyncmsgq_send(i->sink->asyncmsgq, PA_MSGOBJECT(i), PA_SINK_INPUT_MESSAGE_SET_SOFT_VOLUME, NULL, 0, NULL) == 0);
|
||||
|
|
@ -1673,7 +1673,7 @@ static void update_volume_due_to_moving(pa_sink_input *i, pa_sink *dest) {
|
|||
|
||||
pa_cvolume_reset(&new_volume, i->volume.channels);
|
||||
pa_sink_input_set_volume_direct(i, &new_volume);
|
||||
pa_cvolume_reset(&i->reference_ratio, i->reference_ratio.channels);
|
||||
pa_sink_input_set_reference_ratio(i, &new_volume);
|
||||
pa_assert(pa_cvolume_is_norm(&i->real_ratio));
|
||||
pa_assert(pa_cvolume_equal(&i->soft_volume, &i->volume_factor));
|
||||
}
|
||||
|
|
@ -2238,3 +2238,27 @@ void pa_sink_input_set_volume_direct(pa_sink_input *i, const pa_cvolume *volume)
|
|||
pa_subscription_post(i->core, PA_SUBSCRIPTION_EVENT_SINK_INPUT|PA_SUBSCRIPTION_EVENT_CHANGE, i->index);
|
||||
pa_hook_fire(&i->core->hooks[PA_CORE_HOOK_SINK_INPUT_VOLUME_CHANGED], i);
|
||||
}
|
||||
|
||||
/* Called from the main thread. */
|
||||
void pa_sink_input_set_reference_ratio(pa_sink_input *i, const pa_cvolume *ratio) {
|
||||
pa_cvolume old_ratio;
|
||||
char old_ratio_str[PA_CVOLUME_SNPRINT_VERBOSE_MAX];
|
||||
char new_ratio_str[PA_CVOLUME_SNPRINT_VERBOSE_MAX];
|
||||
|
||||
pa_assert(i);
|
||||
pa_assert(ratio);
|
||||
|
||||
old_ratio = i->reference_ratio;
|
||||
|
||||
if (pa_cvolume_equal(ratio, &old_ratio))
|
||||
return;
|
||||
|
||||
i->reference_ratio = *ratio;
|
||||
|
||||
if (!PA_SINK_INPUT_IS_LINKED(i->state))
|
||||
return;
|
||||
|
||||
pa_log_debug("Sink input %u reference ratio changed from %s to %s.", i->index,
|
||||
pa_cvolume_snprint_verbose(old_ratio_str, sizeof(old_ratio_str), &old_ratio, &i->channel_map, true),
|
||||
pa_cvolume_snprint_verbose(new_ratio_str, sizeof(new_ratio_str), ratio, &i->channel_map, true));
|
||||
}
|
||||
|
|
|
|||
Loading…