decrease maximum allowed sample frequency for ALSA devices to 5%, since 48000 would otherwise match with 44100

git-svn-id: file:///home/lennart/svn/public/pulseaudio/trunk@995 fefdeb5f-60dc-0310-8127-8f9354f1896f
This commit is contained in:
Lennart Poettering 2006-05-31 00:05:38 +00:00
parent 9f2026da05
commit 79b6c31f23

View file

@ -284,7 +284,7 @@ int pa_alsa_set_hw_params(snd_pcm_t *pcm_handle, pa_sample_spec *ss, uint32_t *p
pa_log_info(__FILE__": device doesn't support %u Hz, changed to %u Hz.", ss->rate, r); pa_log_info(__FILE__": device doesn't support %u Hz, changed to %u Hz.", ss->rate, r);
/* If the sample rate deviates too much, we need to resample */ /* If the sample rate deviates too much, we need to resample */
if (r < ss->rate*.9 || r > ss->rate*1.1) if (r < ss->rate*.95 || r > ss->rate*1.05)
ss->rate = r; ss->rate = r;
} }