equalizer: Use sink_master as the module argument rather than just master.

This brings more uniformity to arguments to match module-echo-cancel
(which needs both sink and source masters, hence the disambiguation).

This will allow other modules to load filters in a more uniform way
in the future without kludges to deal with variation in arguments.
This commit is contained in:
Colin Guthrie 2011-04-14 13:00:58 +02:00
parent aaab340d4e
commit 34658927a3

View file

@ -79,7 +79,7 @@ PA_MODULE_LOAD_ONCE(FALSE);
PA_MODULE_USAGE(
_("sink_name=<name of the sink> "
"sink_properties=<properties for the sink> "
"master=<sink to connect to> "
"sink_master=<sink to connect to> "
"format=<sample format> "
"rate=<sample rate> "
"channels=<number of channels> "
@ -133,7 +133,7 @@ struct userdata {
static const char* const valid_modargs[] = {
"sink_name",
"sink_properties",
"master",
"sink_master",
"format",
"rate",
"channels",
@ -1088,7 +1088,7 @@ int pa__init(pa_module*m) {
goto fail;
}
if (!(master = pa_namereg_get(m->core, pa_modargs_get_value(ma, "master", NULL), PA_NAMEREG_SINK))) {
if (!(master = pa_namereg_get(m->core, pa_modargs_get_value(ma, "sink_master", NULL), PA_NAMEREG_SINK))) {
pa_log("Master sink not found");
goto fail;
}