mirror of
				https://gitlab.freedesktop.org/pulseaudio/pulseaudio.git
				synced 2025-11-03 09:01:50 -05:00 
			
		
		
		
	null-sink: correct update of timestamp when state changes to RUNNING or IDLE
u->timestamp should be reset to "now" when the sink state changes from INIT or SUSPENDED to IDLE or RUNNING. Thanks to Olivier Delbeke for reporting the bug and testing the patch. Bug report is here: http://lists.freedesktop.org/archives/pulseaudio-discuss/2015-October/024553.html
This commit is contained in:
		
							parent
							
								
									fcbbe34e00
								
							
						
					
					
						commit
						2902cdc4ca
					
				
					 1 changed files with 4 additions and 2 deletions
				
			
		| 
						 | 
				
			
			@ -93,8 +93,10 @@ static int sink_process_msg(
 | 
			
		|||
    switch (code) {
 | 
			
		||||
        case PA_SINK_MESSAGE_SET_STATE:
 | 
			
		||||
 | 
			
		||||
            if (PA_PTR_TO_UINT(data) == PA_SINK_RUNNING)
 | 
			
		||||
                u->timestamp = pa_rtclock_now();
 | 
			
		||||
            if (pa_sink_get_state(u->sink) == PA_SINK_SUSPENDED || pa_sink_get_state(u->sink) == PA_SINK_INIT) {
 | 
			
		||||
                if (PA_PTR_TO_UINT(data) == PA_SINK_RUNNING || PA_PTR_TO_UINT(data) == PA_SINK_IDLE)
 | 
			
		||||
                    u->timestamp = pa_rtclock_now();
 | 
			
		||||
            }
 | 
			
		||||
 | 
			
		||||
            break;
 | 
			
		||||
 | 
			
		||||
| 
						 | 
				
			
			
 | 
			
		|||
		Loading…
	
	Add table
		Add a link
		
	
		Reference in a new issue