SysEx in UMP can span multiple packets. In MIDI1 we can't split them up
into multiple events so we need to collect the complete sysex and then
write out the event.
Fixes SysEx writes to ALSA seq by running the event encoder until a
valid packet is completed.
Also fixes split MIDI1 packets in the JACK API when going through the