Wim Taymans 4a90facafe pipewire-jack: only call timebase with valid buffer_frames
If the status passed to cycle_signal != 0 we should not call the
timebase callback. We already do this but we can use this fact to also
not call the timebase_callback when there was no buffer_frames
configured yet.

Do this by setting the fallback return value of process_callback to != 0.
When there is no buffer_frames yet, this will be used.

Also set the buffer_frames to the invalid value of -1 in jack_activate
instead of 0. -1 is the invalid value we check everywhere else.
2026-03-19 13:23:13 +01:00
..
examples pipewire-jack: examples: video-dsp-play: add missing includes 2025-02-02 14:25:08 +01:00
jack jack: use a new JackPortIsMIDI2 flag 2025-01-27 13:05:21 +01:00
src pipewire-jack: only call timebase with valid buffer_frames 2026-03-19 13:23:13 +01:00
meson.build [Meson] Change jack-devel option to be boolean 2021-08-06 07:56:16 +00:00