This property is exposed on the device Route and forwarded to the
nodes. It then configured the process_latency.ns field, which
influences the reported port latency.
This makes it possible to change the internal port latency on the
sink and source with pavucontrol and tweak the synchronization to
compensate for internal latencies in the device.
Use _alibpref to check if a device needs a UCM local config. Mark
the device as such and use this to set the OPEN_UCM property on
the device.
Open the UCM for a card when the device has the property set. Use the
same logic for loading the UCM as the acp code.
See #1251
UCM devices can require local data from use_case_mgr_open() but since
we do that in a separate process, make sure we reopen the use case
manager in case we are passed a UCM device so that the config is
available.
See #1251
When we add a new listener to an object, it will emit the full state
of the object. For this it temporarily sets the change_mask to all
changes. Restore the previous state after this or else we might not
emit the right change_mask for the next listener.
Consider the case where one there are two listeners on an object.
The object emits a change and the first listener wants to enumerate the
changed params. For this is adds a new listener and then triggers the
enumeration. If we set the change_mask to 0 after adding the listener,
the second listener would get a 0 change_mask and fail to update
its state.
This replaces the manual check for "true" and some (inconsistent) return value
of atoi. All those instances now require either "true" or "1" to parse as
true, any other value (including NULL) is boolean false.
When we start freewheeling, pause the device and resume when we
finish freewheel.
In freewheel mode, just discard samples in the sink and produce
silence in the source.
Make info parsing a bit easier to read by assigning the key and
value to temporary variables.
Improve the parsing of channelmap using json parser to make it
support more cases.
Add a unit test for channelmap parsing options.
node.latency also influences the pipeline latency in that it can
push the latency above the default value.
node.max-latency, instead, is only used to clamp the final latency
of the pipeline.
Use these commands to mark the begin and end of a series of Param
enumerations and configuration, like when doing format negotiation. The
idea is that the device can remain open while we do this.
Use this in adapter when negotiating a format.
We only set the OUT flag when we put the buffer on an io area and
might need to recycle later.
Before placing the output buffer into the io area, recycle any
buffer that might be left in there.
Only emit the ready callback when we have some data queued.
This is more in line with wayland and it allows us to create new
interfaces in modules without having to add anything to the type
enum. It also removes some lookups to map type_id to readable
name in debug.
Add a clock name to the clock, remove the old api/clock_id. This makes
it easier to add descriptive names
Place the alsa card number in the clock name.
Check the clock name of the master clock and if it matches our own
clock, disable rate matching.