DSD64 would be a rate of 44100 * 64 / 8. When packed in U32_BE, we would
negotiate 44100 * 8 / 4 (88200) with the device, this means all rates
from 88200 and up are allowed for DSD64 in U32_BE.
When the device is not running but has a format, close/open the
device to get all the available formats again. Do the same when
setting a format.
Otherwise, the configuration space of the device is restricted to the
current negotiated format and we can't query the other possibilities
or change it.
Fixes#2625
Only update the resampler rate when we ask for more data, when we have
more input data, use the previously configured rate to calculate how
many samples we will consume.
Fixes resync errors with multiple sources. One source would do rate
matching, audioconvert would ask it to produce X samples, the source is
scheduled to produce the samples, the rate match is updated with the new
rate correction, audioconvert is scheduled again. It should now use the
X samples it asked to produce and apply the new rate correction for the
next iteration.
If no packets have been received and spa_bt_decode_buffer_process is
called, this->packet_size.max == INT32_MIN, which can give overflows.
Guard against this condition, although it should be harmless.
At the moment, cross compilation may not work in certain cases because
checks are carried out against the build machine instead of the host machine.
Replace uses of `build_machine` with `host_machine` to fix that.
In native compilation, all three "machine objects" available in meson
are the same, so this change should have no effect in that case.
More: https://mesonbuild.com/Cross-compilation.html
React immediately to "bad" buffer level. Use smaller bitrate
increments/decrements. Fix ABR timer increment for fragmented packets.
Handle actual bitrate being smaller than target during silence.
Only simple upmixing would replicate the FC channel into REAR/SIDE.
The PSD method would take the diff between FL/FR (which would
be 0 if only FC is available) and not generate output.
Always use the DSP rate on DSP ports for format conversion, not the
previous used rate.
This avoids some resampler reconfiguration as it negotiates a non-passthrough
rate conversion and then switches to passthrough when the rate correction is
done to match the graph rate.
See #2614