mirror of
https://gitlab.freedesktop.org/pipewire/pipewire.git
synced 2025-11-26 07:00:13 -05:00
spa: bluez: backend-native: Fix BIEV HF indicators support for HFP AG
The "+BIND: <a>,<state>" reply to AT+BIND? should be sent for every supported indicator. "AT+BIEV= <assigned number>,<value>" should only be provided for enabled indicators. The AG shall respond with an ERROR response code if it receives updates for disabled or unknown HF indicators or values that are out of bounds. This allows to pass PTs tests: - HFP/AG/HFI/BV-02-C AG receives an updated HF Indicator value - HFP/AG/HFI/BI-03-C AG receives invalid updated HF Indicator values
This commit is contained in:
parent
1408dd5245
commit
6ced56e11d
1 changed files with 5 additions and 1 deletions
|
|
@ -1010,6 +1010,7 @@ static void process_hfp_hf_indicator(struct rfcomm *rfcomm, unsigned int indicat
|
|||
|
||||
switch (indicator) {
|
||||
case SPA_BT_HFP_HF_INDICATOR_ENHANCED_SAFETY:
|
||||
rfcomm_send_error(rfcomm, CMEE_AG_FAILURE);
|
||||
break;
|
||||
case SPA_BT_HFP_HF_INDICATOR_BATTERY_LEVEL:
|
||||
// Battery level is reported in range 0-100
|
||||
|
|
@ -1018,12 +1019,15 @@ static void process_hfp_hf_indicator(struct rfcomm *rfcomm, unsigned int indicat
|
|||
if (value <= 100) {
|
||||
// TODO: report without Battery Provider (using props)
|
||||
spa_bt_device_report_battery_level(rfcomm->device, value);
|
||||
rfcomm_send_reply(rfcomm, "OK");
|
||||
} else {
|
||||
spa_log_warn(backend->log, "battery HF indicator %u outside of range [0, 100]: %u", indicator, value);
|
||||
rfcomm_send_error(rfcomm, CMEE_AG_FAILURE);
|
||||
}
|
||||
break;
|
||||
default:
|
||||
spa_log_warn(backend->log, "unknown HF indicator:%u value:%u", indicator, value);
|
||||
rfcomm_send_error(rfcomm, CMEE_AG_FAILURE);
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
|
@ -1350,6 +1354,7 @@ next_indicator:
|
|||
rfcomm_send_reply(rfcomm, "+BIND: (2)");
|
||||
rfcomm_send_reply(rfcomm, "OK");
|
||||
} else if (spa_strstartswith(buf, "AT+BIND?")) {
|
||||
rfcomm_send_reply(rfcomm, "+BIND: 1,0");
|
||||
rfcomm_send_reply(rfcomm, "+BIND: 2,1");
|
||||
rfcomm_send_reply(rfcomm, "OK");
|
||||
} else if (spa_strstartswith(buf, "AT+BIND=")) {
|
||||
|
|
@ -1359,7 +1364,6 @@ next_indicator:
|
|||
rfcomm_send_reply(rfcomm, "OK");
|
||||
} else if (sscanf(buf, "AT+BIEV=%u,%u", &indicator, &indicator_value) == 2) {
|
||||
process_hfp_hf_indicator(rfcomm, indicator, indicator_value);
|
||||
rfcomm_send_reply(rfcomm, "OK");
|
||||
} else if (sscanf(buf, "AT+XAPL=%04x-%04x-%*[^,],%u", &xapl_vendor, &xapl_product, &xapl_features) == 3) {
|
||||
if (xapl_features & SPA_BT_HFP_HF_XAPL_FEATURE_BATTERY_REPORTING) {
|
||||
/* claim, that we support battery status reports */
|
||||
|
|
|
|||
Loading…